N429JS1995 Dornier Luftfahrt Gmbh 328-100

DeregisteredUnclaimedSource: FAA, updated Oct 18, 2026

This N-number isn't registered right now. Below is its last known registration, canceled Jun 29, 2009.

Safety record in brief:No NTSB accidents or incidents since 198219 ADs may apply65 service difficulty reports

Registration
Deregistered
Last based in
San Antonio, TX
owner city / state
Engine
PW119B · 1851 hp
P&W Canada
Owners
1
since 2007
NTSB events
None
since 1982
ADs may apply
19
confirm with A&P
Service reports
65
since 1995

Registration

FAA Aircraft Registry · Oct 18, 2026
Last registered owner
Comtran International INC
Owner type
Corporation
City, state
San Antonio, TX
Certificate issued
Oct 11, 2007
Canceled
Jun 29, 2009
Airworthiness
Standard · Transport
Airworthiness date
Jun 8, 1995

We never show street addresses, even though they appear in the public FAA file. Individual owners are shown by city and state only.

Airframe & engine

FAA Registry + type data

Airframe

Manufacturer
Dornier Luftfahrt Gmbh
Model
328-100
Year
1995
Serial number
3043
Aircraft type
Fixed wing multi engine
Category
Land
Certification
Type Certificated
Seats
36
Engines
2
Max takeoff weight
20,000 and over lb
Mode S code
A51DE7

Engine

Make and model
P&W Canada Pw119b
Type
Turbo-prop
Power
1851 hp

Total time and engine hours aren't public. They appear here once the owner adds logbooks.

Ownership history

Ownership history from FAA records
  1. 2007 – 2009Comtran International INCSan Antonio, TX

Individual owners are shown by city and state only.

Safety record

NTSB · Oct 15, 2026 · FAA ADs · Oct 18, 2026 · SDRs · Oct 16, 2026

NTSB events (0)

No NTSB accidents or incidents found for this airframe since 1982.

Accident history for this model

ADs published since 1998 that may apply (19)

These match the airframe or engine model. Whether each one applies, and whether it's been complied with, depends on serial numbers, equipment and logbook entries. Applicability must be confirmed by a mechanic against the aircraft's records.

ADSubjectEffectiveApplies to
2025-15-05FuelSep 3, 2025Airframe (328-100)
2025-06-08Landing gearMay 8, 2025Airframe (328-100)
2024-19-16Equipment/ furnishingsNov 26, 2024Airframe (328-100)
2023-23-07Deutsche Aircraft GmbH (Type Certificate Previously Held by 328 Support Services GmbH…Jan 16, 2024Airframe (328-100)
2023-22-07Deutsche Aircraft GmbH (Type Certificate Previously Held by 328 Support Services GmbH…Dec 26, 2023Airframe (328-100)
Show all 19 ADs
ADSubjectEffectiveApplies to
2022-21-07Placards and markings and 25, Equipment/furnishingsDec 15, 2022Airframe (328-100)
2020-07-20Time Limits/ Maintenance ChecksMay 26, 2020Airframe (328-100)
2019-24-14WingsFeb 3, 2020Airframe (328-100)Certain serial numbers: 328-100 3032–3063
2019-15-03WingsSep 19, 2019Airframe (328-100)
2018-19-13StabilizersOct 31, 2018Airframe (328-100)
2017-21-06FuelDec 20, 2017Airframe (328-100)
2014-03-15Placards and Markings; and Code 52, DoorsApr 9, 2014Airframe (328-100)Certain serial numbers: 328-100 3005–3101; 328-100 3103; 328-100 3104; 328-100 3106; 328-100 3109; 328-100 3110; …
2013-15-08Pratt & Whitney Canada Corp. Turboprop EnginesSep 17, 2013Engine (PW119B)Serial numbers per Table 1 of the Appendix of P&WC Service Bulletin No. PW100-72-21823, Revision 3. Only with: First-stage power turbine blade P/N 3120973-01, 3120983-01, or 3054053-01 installed with a serial number listed in the referenced SB table.
2012-26-08Pratt & Whitney Canada Corp. Turboprop EnginesFeb 15, 2013Engine (PW119B)Serial numbers per P&WC ASB No. PW100-72-A21813 Rev 3, PW100-72-A21802 Rev 4, and PW100-72-A21798 Rev 5. Only with: Engines with propeller shafts having serial numbers listed in the referenced P&WC ASBs.
2012-07-03Equipment/ FurnishingsMay 10, 2012Airframe (328-100)
2012-04-06Engine ControlsApr 4, 2012Airframe (328-100)
2011-18-13328 Support Services GmbH (Type Certificate Previously Held by AvCraft Aerospace GmbH…Oct 25, 2011Airframe (328-100)
2011-15-07328 Support Services GmbH (Type Certificate Previously Held by AvCraft Aerospace GmbH…Aug 22, 2011Airframe (328-100)
2011-01-07328 Support Services GmbH (Type Certificate Previously Held by AvCraft Aerospace GmbH…Feb 9, 2011Airframe (328-100)Only with: 328-100 with aileron trim tab fittings P/N 001B576A2101000 (LH) or 001B576A2101003 (RH), or rudder spring tab fitting P/N 001A554A1711000 installed; 328-300 with aileron trim tab fittings P/N 001B576A2101000 (LH) or 001B576A2101003 (RH) installed.

AI-extracted — verify against original. Matched from each AD's applicability section; ADs replaced by a later AD are left out.

Service Difficulty Reports (65)

Reports of failures and defects that operators and repair stations sent to the FAA since 1995. A report describes one finding; it is not an accident.

  • Landing gear · valve · failedJul 26, 2004

    DURING CLIMBOUT, THE CREW RECEIVED A EMERGENCY PARKING BRAKE ACCUMULATOR LOW CAS MESSAGE AND RETURNED TO PHL. MAINTENANCE CONTROL FERRIED THE AIRCRAFT TO PIT. MAINTENANCE INSPECTED AND REPLACED THE EMERGENCY PARKING BRAKE VALVE IN ACCORDANCE WITH DORNIER MAITNENANCE MANUAL 32-00-00. OPERATIONAL…

    From FAA Service Difficulty Reports; matched by N-number and serial number.
  • Electrical power · terminal block · failedJun 21, 2004

    THE CREW REPORTED SMOKE IN THE COCKPIT. MAINTENANCE INSPECTED AND REPLACED FUSES AND A TERMINAL BLOCK UNDER THE CAPTAIN'S SEAT IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 24-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAS RELEASED FOR SERVICE.

    From FAA Service Difficulty Reports; matched by N-number and serial number.
  • Lights · power supply · failedJun 2, 2004

    THE CREW REPORTED THAT DURING THE EMERGENCY POWER SUPPLY TEST, ONLY THE TOP LIGHT CAME ON. MAINTENANCE INSPECTED AND REPLACED THE FORWARD EMERGENCY POWER SUPPLY IN ACCORDANCE WITH DORNIER MAINTENACE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAS RELEASED FOR SERVICE.

    From FAA Service Difficulty Reports; matched by N-number and serial number.
Show all 10 reports
  • Flight controls · pin · installedApr 19, 2004

    FLIGHT 2597 RETURNED TO GATE WITH RUDDER PEDDLES JAMMED. MAINTENANCE INSPECTED AND REMOVED RIG PIN FROM RUDDER PEDDLES IN ACCORDANCE WITH THE DORNIER MAINTENANCE MANUAL 32-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT RELEASED FOR SERVICE.

    From FAA Service Difficulty Reports; matched by N-number and serial number.
  • Landing gear · pseu · malfunctionedFeb 16, 2004

    DURING TAKEOFF, THE CREW RECEIVED A NOSE WHEEL STEERING FAIL AND PROXY SYSTEM FAILED AND THE CREW ABORTED TAKEOFF. MAINTENANCE INSPECTED AND RERACKED THE PSEU IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 32-00-00. TAXI CHECKS WERE PERFORMED AND THE AIRCRAFT WAS THEN RELEASED FOR SERVICE.

    From FAA Service Difficulty Reports; matched by N-number and serial number.
  • Flight controls · actuator · failedJan 21, 2004

    DURING FLIGHT CREW RECEIVED A PITCH TRIM ASSYM CAS MESSAGE. AIRCRAFT RETURNED TO PHL. MAINTENANCE INSPECTED AND CHANGED THE LT AND RT ELEVATOR TRIM ACTUATOR IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 27-00-00. OPERATIONAL CHECKS WERE DONE ACCORDING TO DORNIER MAINTENANCE MANUAL 27-00-00.…

    From FAA Service Difficulty Reports; matched by N-number and serial number.
  • Lights · battery · failedNov 11, 2003

    THE CREW REPORTED THAT THE EMERGENCY LIGHTING AT ROWS 6 TO 9 WERE NOT ILLUMINATING. MAINTENANCE INSPECTED AND REPLACED THE 6LK EMERGENCY BATTERY IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAS RELEASED FOR SERVICE.

    From FAA Service Difficulty Reports; matched by N-number and serial number.
  • Lights · battery · failedOct 22, 2003

    THE CREW REPORTED THAT THE EMERGENCY EXIT SIGN AND BOARDING LIGHTS FADE. MAINTENANCE INSPECTED AND REPLACED THE 6LK EMERGENCY BATTERY IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAS RLEASED FOR SERVICE.

    From FAA Service Difficulty Reports; matched by N-number and serial number.
  • Electrical power · control panel · failedSep 30, 2003

    DURING TAKEOFF, THE CREW RECEIVED A LEFT HAND GENERATOR FAIL MESSAGE AND ABORTED TAKEOFF. THE AIRCRAFT WAS THEN FERRIED TO PIT WHERE MAINTENANCE INSPECTED AND REPLACED THE 1VE PANEL IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 24-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAS…

    From FAA Service Difficulty Reports; matched by N-number and serial number.
  • Lights · battery · dischargedSep 21, 2003

    THE CREW REPORTED THAT THE EMERGENCY LIGHTING AT ROWS 6 AND 9 WERE NOT WORKING. MAINTENANCE INSPECTED AND REPLACED THE EMERGENCY BATTERY IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAS RELEASED FOR SERVICE.

    From FAA Service Difficulty Reports; matched by N-number and serial number.

Showing the 10 most recent of 65 reports.

Sources

  • FAA Aircraft RegistryRegistration, owner city and state, airframe, engineupdated Oct 18, 2026
  • NTSB accident and incident databaseAccidents and incidents since 1982updated Oct 15, 2026
  • FAA Airworthiness Directives (Federal Register)ADs published since 1998updated Oct 18, 2026
  • FAA Service Difficulty ReportsReports since 1995updated Oct 16, 2026

Request owner name removalReport an error in this record